LF
SPIN ON TYPE FILTERS FOR COMPRESSED AIR
Flow rate: 33 ÷ 588 m3/h
The LF range of compressed air filters offers extremely easy maintenance and replacement of filter elements.
Share
The LF range of compressed air filters offers extremely easy maintenance and replacement of filter elements. Four filtration degrees are available to meet air quality requirements under ISO 8573.1. The LF filter special feature can be found in the filter body. Unlike conventional filters on the market, it is a cartridge, which becomes a single, disposable Spin On element. The water-repellent pleated borosilicate filtering part is one of the best products for compressed air filtration. This unique and high-quality product features an anodised aluminium head. The filtration model and grade instructions are screen-printed on the filter body.
Main components
- Filter head in anodized aluminum
- Metal container
- Borosilicate pleated cartridge
MAXIMUM WORKING CONDITIONS
- Ambient temperature: + 60°C
- Inlet air pressure: 16 barg (LF*006÷045), 14 barg(LF*061) and 11 barg (LF*100)
- Inlet air temperature: + 60°C
INSTALLATION DIAGRAM
Data refer to the following nominal condition: inlet air pressure 7 barg; inlet air temperature +35 °C.
[*] Filtration grade: P (5 micron); S (1 micron); X (0.01 micron); Z (carbon attivo).
Filtration Grade | Air Quality | Application example |
P SERIES – 5 MICRON | Filter capable to separate emulsion and particles down to 5 micron. | Normally installed on the inlet of dryers. Ideal as pre-filter for on-line filters (series S-X-Z), and for vacuum pumps, pneumatic blowing plants. |
S SERIES 1 MICRON | Filter capable to separate particles down to 1 micron, liquid and oil included.Maximum contents of residual oil 0,1 mg/m3 | Normally used on outlet of dryers as X grade pre-filter. Used to prevent the deterioration of the pipes of compressed air plants, for surface treatment, on vacuum pump exhaust, on compressed air motors. and as post-filter for adsorption dryers. |
X SERIES 0,01 MICRON | Oil removing filter capable to separate residual oil and extremely small particles down to 0,01 mg/m3. 3It produces air technical free from oil. | Normally used as a pre filter at the entrance of the dryer by absorption and active carbon filters; post filter at the delivery of the frigorific cycle dryers. Also ideal for the protection of the control systems, pneumatic transport, varnishing systems, etc. |
Z SERIES Activated carbon | Activated carbon filter for the elimination of oil vapours and odour. When installed, after a X grade filter, it lowers the maximum contents of residual oil 0,005 mg/m3.3 | Used in the pharmaceutical industry, for dental applications, in photographic workshops, packaging and galvanic treatments. |
MDR04
Manual condensate drain
ATD02
Automatic mini float condensate drain
SCG20
Automatic float condensate drain
SCE04
Automatic timed condensate drain
SEC11
Zero Loss Drain
CLI01
Clogging indicators
CLI03
Clogging indicator with volt free electric contact
DIG03
Differential gauge Ø50 mm
Main features
The LF range of compressed air filters offers extremely easy maintenance and replacement of filter elements. Four filtration degrees are available to meet air quality requirements under ISO 8573.1. The LF filter special feature can be found in the filter body. Unlike conventional filters on the market, it is a cartridge, which becomes a single, disposable Spin On element. The water-repellent pleated borosilicate filtering part is one of the best products for compressed air filtration. This unique and high-quality product features an anodised aluminium head. The filtration model and grade instructions are screen-printed on the filter body.
Main components
- Filter head in anodized aluminum
- Metal container
- Borosilicate pleated cartridge
MAXIMUM WORKING CONDITIONS
- Ambient temperature: + 60°C
- Inlet air pressure: 16 barg (LF*006÷045), 14 barg(LF*061) and 11 barg (LF*100)
- Inlet air temperature: + 60°C
INSTALLATION DIAGRAM
Technical Data
Data refer to the following nominal condition: inlet air pressure 7 barg; inlet air temperature +35 °C.
[*] Filtration grade: P (5 micron); S (1 micron); X (0.01 micron); Z (carbon attivo).
Filtration Grade
Filtration Grade | Air Quality | Application example |
P SERIES – 5 MICRON | Filter capable to separate emulsion and particles down to 5 micron. | Normally installed on the inlet of dryers. Ideal as pre-filter for on-line filters (series S-X-Z), and for vacuum pumps, pneumatic blowing plants. |
S SERIES 1 MICRON | Filter capable to separate particles down to 1 micron, liquid and oil included.Maximum contents of residual oil 0,1 mg/m3 | Normally used on outlet of dryers as X grade pre-filter. Used to prevent the deterioration of the pipes of compressed air plants, for surface treatment, on vacuum pump exhaust, on compressed air motors. and as post-filter for adsorption dryers. |
X SERIES 0,01 MICRON | Oil removing filter capable to separate residual oil and extremely small particles down to 0,01 mg/m3. 3It produces air technical free from oil. | Normally used as a pre filter at the entrance of the dryer by absorption and active carbon filters; post filter at the delivery of the frigorific cycle dryers. Also ideal for the protection of the control systems, pneumatic transport, varnishing systems, etc. |
Z SERIES Activated carbon | Activated carbon filter for the elimination of oil vapours and odour. When installed, after a X grade filter, it lowers the maximum contents of residual oil 0,005 mg/m3.3 | Used in the pharmaceutical industry, for dental applications, in photographic workshops, packaging and galvanic treatments. |
Brochure
Options and Accesories
MDR04
Manual condensate drain
ATD02
Automatic mini float condensate drain
SCG20
Automatic float condensate drain
SCE04
Automatic timed condensate drain
SEC11
Zero Loss Drain
CLI01
Clogging indicators
CLI03
Clogging indicator with volt free electric contact
DIG03