image
Click to enlarge
Back to the product list

CWE

CHILLERS

from 13 to 140 kW

CWE water chillers are air-cooled with axial fans and consist of 14 basic models with cooling capacities from 13 to 140 kW...

CWE are water chillers air-cooled with axial fans and consist of 13 basic models with cooling capacities from 13 to 140 kW. They are designed to specifically meet industrial application requirements and provide accurate control of chilled water temperatures with absolute reliability in terms of continuous operation.

All standard units are equipped with:

  • Hermetic scroll compressors
  • Plate evaporator
  • Water strainer
  • Micro-channel aluminium or finned tubes condensers
  • Fans with step control
  • Microprocessor controller (electronic thermostat for QBE002)
  • RS485 port for modbus connections

EASY MAINTENANCE

The particular architecture of the aeraulic section (the fans are confined in a protected volume) allows safely access to the hydraulic section and to the compressor’s housing.

The clear arrangement of the components, the simplicity of the refrigerant and hydraulic circuit and the identified cabled in the electrical system, assist the users normal operating schedule.

Control and/or maintenance operations could be carried out when the machine is operating and in total safety.

ALTERNATIVE REFRIGERANT GAS

As an alternative to R410A, the CEN range is available with eco-friendly R454B refrigerant gas, with low environmental impact and GWP (global warming potential) of 466.

VARIABLE HEAT RECOVERY SYSTEM

CWE chillers are available, in option, with the innovative HEAT BALANCE variable heat recovery system. The system is self-adaptive, able to satisfy different hot water demands.

Learn more about Heat Balance.

Data referred to: water temp. in/out: 12/7°C – ambient air temp. 35°C
SEPR HT Data are in accordance with European Regulation (EU) 2016/2281 for eco-design requirements.
The complete technical data can be found in the product brochure.

The CWE chiller series is highly configurable:

  • Leaving water temperature stability (+/- 0,1 K) electronic hot gas by-pass valve (only for CWE036÷140)
  • P2/P3/P5 Single or double pump
  • Non-ferrous water circuit;
  • Pressurized water tank
  • Non ferrous water circuit Additional atmospheric water tank kit (glycol charge)
  • Disconnector tank with P2/ P3/ P5 Pump (pressurized carbon steel tank included)
  • Mechanical water level
  • Automatic water bypass valve
  • Anti-freeze heaters
  • Electrical switchboard anti-condensation heater
  • Solenoid valve on liquid line
  • Electronic thermostatic valve
  • Continuous fan(s) speed control – phase cut type (minimum ambient temperature -8.0°C)
  • Continuous fan(s) speed control – electronic fan(s) (minimum ambient temperature -10.0°C)
  • Low ambient temperature kit (minimum ambient temperature -20°C)
  • Full or partial heat recovery
  • Full heat recovery
  • Partial heat recovery
  • Ductable axial electronic fan(s)
  • Shut-off valves
  • Copper tubes&fins condenser
  • Condenser anti-corrosion treatment
  • Double setpoint (from MODBUS and/or keyboard)
  • Water heaters
  • Compressor (s) acoustic shield (s) (only for CWE026÷140)
  • Automatic water filling kit for units with atmospheric water tank
  • Brine kit: thermal insulation of hydraulic pipes fittings and pumps for low temperature units
  • Wind baffles kit
  • Threaded water connections (GAS)
  • Automatic water filling kit
  • Rubber anti-vibration mountings kit
  • Remote Panel
  • Sequencer for modular units
  • RS485 Isolator
  • Water check valve and interlocked solenoid valve
  • Wheels kit

Main features

CWE are water chillers air-cooled with axial fans and consist of 13 basic models with cooling capacities from 13 to 140 kW. They are designed to specifically meet industrial application requirements and provide accurate control of chilled water temperatures with absolute reliability in terms of continuous operation.

All standard units are equipped with:

  • Hermetic scroll compressors
  • Plate evaporator
  • Water strainer
  • Micro-channel aluminium or finned tubes condensers
  • Fans with step control
  • Microprocessor controller (electronic thermostat for QBE002)
  • RS485 port for modbus connections

EASY MAINTENANCE

The particular architecture of the aeraulic section (the fans are confined in a protected volume) allows safely access to the hydraulic section and to the compressor’s housing.

The clear arrangement of the components, the simplicity of the refrigerant and hydraulic circuit and the identified cabled in the electrical system, assist the users normal operating schedule.

Control and/or maintenance operations could be carried out when the machine is operating and in total safety.

ALTERNATIVE REFRIGERANT GAS

As an alternative to R410A, the CEN range is available with eco-friendly R454B refrigerant gas, with low environmental impact and GWP (global warming potential) of 466.

VARIABLE HEAT RECOVERY SYSTEM

CWE chillers are available, in option, with the innovative HEAT BALANCE variable heat recovery system. The system is self-adaptive, able to satisfy different hot water demands.

Learn more about Heat Balance.

Cooling Capacity & Energy Efficiency

Data referred to: water temp. in/out: 12/7°C – ambient air temp. 35°C
SEPR HT Data are in accordance with European Regulation (EU) 2016/2281 for eco-design requirements.
The complete technical data can be found in the product brochure.

Kit and options

The CWE chiller series is highly configurable:

  • Leaving water temperature stability (+/- 0,1 K) electronic hot gas by-pass valve (only for CWE036÷140)
  • P2/P3/P5 Single or double pump
  • Non-ferrous water circuit;
  • Pressurized water tank
  • Non ferrous water circuit Additional atmospheric water tank kit (glycol charge)
  • Disconnector tank with P2/ P3/ P5 Pump (pressurized carbon steel tank included)
  • Mechanical water level
  • Automatic water bypass valve
  • Anti-freeze heaters
  • Electrical switchboard anti-condensation heater
  • Solenoid valve on liquid line
  • Electronic thermostatic valve
  • Continuous fan(s) speed control – phase cut type (minimum ambient temperature -8.0°C)
  • Continuous fan(s) speed control – electronic fan(s) (minimum ambient temperature -10.0°C)
  • Low ambient temperature kit (minimum ambient temperature -20°C)
  • Full or partial heat recovery
  • Full heat recovery
  • Partial heat recovery
  • Ductable axial electronic fan(s)
  • Shut-off valves
  • Copper tubes&fins condenser
  • Condenser anti-corrosion treatment
  • Double setpoint (from MODBUS and/or keyboard)
  • Water heaters
  • Compressor (s) acoustic shield (s) (only for CWE026÷140)
  • Automatic water filling kit for units with atmospheric water tank
  • Brine kit: thermal insulation of hydraulic pipes fittings and pumps for low temperature units
  • Wind baffles kit
  • Threaded water connections (GAS)
  • Automatic water filling kit
  • Rubber anti-vibration mountings kit
  • Remote Panel
  • Sequencer for modular units
  • RS485 Isolator
  • Water check valve and interlocked solenoid valve
  • Wheels kit