imageimage
Click to enlarge
preview
preview
Back to the product list

HWE

REVERSIBLE HEAT PUMPS / CHILLERS

from 13 to 140 kW in cooling mode

HWE reversible heat pumps are air-cooled with axial fans and consist of 14 basic models with cooling capacities in the range of 13 to...

HWE reversible heat pumps are air-cooled with axial fans and consist of 14 basic models with cooling capacities in the range of 13 to 140 kW. They are designed to specifically meet industrial application requirements and provide accurate control of chilled water temperatures with absolute reliability in terms of continuous operation. All standard units are equipped with:

  • Hermetic scroll compressors
  • Stainless steel brazed plates heat-exchanger
  • Copper and aluminium ventilated coils with hydrophilic treatment on fins
  • Fans with step control
  • Microprocessor controller (electronic thermostat for QBE002)
  • RS485 port for modbus connections

EASY MAINTENANCE

Theparticular architecture of the aeraulic section (the fans are confined in a protected volume) allows safely access to the hydraulic section and to the compressor’s housing.

The clear arrangement of the components, the simplicity of the refrigerant and hydraulic circuit and the identified cabled in the electrical system, assist the users normal operating schedule.

Control and/or maintenance operations could be carried out when the machine is operating and in total safety.

ALTERNATIVE REFRIGERANT GAS

As an alternative to R410A, the HWE range is available with eco-friendly R454B refrigerant gas, with low environmental impact and GWP (global warming potential) of 466.

Data referred to: Inlet-outlet water temp. 20/15°C – Air temp.: 25°C in liquid chiller version
Inlet-outlet water temp. 40/45°C – Air temp.: 7°C in version heat pump.
The EER/COP data meet the requirements of the European Regulation (EU) 2016/2281 for eco-design.
The complete technical data can be found in the product brochure.

The HWE chiller series is highly configurable:

  • Single / Double P2/P3/P5 Pump
  • Non-ferrous water circuit;
  • Pressurized water tank
  • Non ferrous water circuit Additional atmospheric water tank kit (glycol charge)
  • Non ferrous atmospheric water circuit (plastic water tank)
  • Disconnector tank with P2/ P3/ P5 Pump (pressurized carbon steel tank included)
  • Mechanical water level
  • Automatic water bypass valve
  • Anti-freeze heaters
  • Electrical switchboard anti-condensation heater
  • Electronic thermostatic valve
  • Continuous fan(s) speed control – phase cut type (minimum ambient temperature -8.0°C)
  • Continuous fan(s) speed control – electronic fan(s) (min. ambient temp. -10.0°C)
  • Low ambient temperature kit (minimum ambient temperature -20°C)
  • Full or partial heat recovery
  • Full heat recovery
  • Ductable axial electronic fan(s)
  • Shut-off valves
  • Copper tubes&fins condenser
  • Condenser anti-corrosion treatment
  • Double setpoint (from MODBUS and/or keyboard)
  • Water heaters
  • Compressor (s) acoustic shield (s) (only for HWE026÷140)
  • Automatic water filling kit for units with atmospheric water tank
  • Brine kit: thermal insulation of hydraulic pipes fittings and pumps for low temperature units
  • Wind baffles kit
  • Threaded water connections kit (GAS)
  • Automatic water filling kit
  • Rubber anti-vibration mountings kit
  • Remote Panel
  • Sequencer for modular units
  • Wheels kit

Main features

HWE reversible heat pumps are air-cooled with axial fans and consist of 14 basic models with cooling capacities in the range of 13 to 140 kW. They are designed to specifically meet industrial application requirements and provide accurate control of chilled water temperatures with absolute reliability in terms of continuous operation. All standard units are equipped with:

  • Hermetic scroll compressors
  • Stainless steel brazed plates heat-exchanger
  • Copper and aluminium ventilated coils with hydrophilic treatment on fins
  • Fans with step control
  • Microprocessor controller (electronic thermostat for QBE002)
  • RS485 port for modbus connections

EASY MAINTENANCE

Theparticular architecture of the aeraulic section (the fans are confined in a protected volume) allows safely access to the hydraulic section and to the compressor’s housing.

The clear arrangement of the components, the simplicity of the refrigerant and hydraulic circuit and the identified cabled in the electrical system, assist the users normal operating schedule.

Control and/or maintenance operations could be carried out when the machine is operating and in total safety.

ALTERNATIVE REFRIGERANT GAS

As an alternative to R410A, the HWE range is available with eco-friendly R454B refrigerant gas, with low environmental impact and GWP (global warming potential) of 466.

Cooling Capacity & Energy Efficiency

Data referred to: Inlet-outlet water temp. 20/15°C – Air temp.: 25°C in liquid chiller version
Inlet-outlet water temp. 40/45°C – Air temp.: 7°C in version heat pump.
The EER/COP data meet the requirements of the European Regulation (EU) 2016/2281 for eco-design.
The complete technical data can be found in the product brochure.

Kit and options

The HWE chiller series is highly configurable:

  • Single / Double P2/P3/P5 Pump
  • Non-ferrous water circuit;
  • Pressurized water tank
  • Non ferrous water circuit Additional atmospheric water tank kit (glycol charge)
  • Non ferrous atmospheric water circuit (plastic water tank)
  • Disconnector tank with P2/ P3/ P5 Pump (pressurized carbon steel tank included)
  • Mechanical water level
  • Automatic water bypass valve
  • Anti-freeze heaters
  • Electrical switchboard anti-condensation heater
  • Electronic thermostatic valve
  • Continuous fan(s) speed control – phase cut type (minimum ambient temperature -8.0°C)
  • Continuous fan(s) speed control – electronic fan(s) (min. ambient temp. -10.0°C)
  • Low ambient temperature kit (minimum ambient temperature -20°C)
  • Full or partial heat recovery
  • Full heat recovery
  • Ductable axial electronic fan(s)
  • Shut-off valves
  • Copper tubes&fins condenser
  • Condenser anti-corrosion treatment
  • Double setpoint (from MODBUS and/or keyboard)
  • Water heaters
  • Compressor (s) acoustic shield (s) (only for HWE026÷140)
  • Automatic water filling kit for units with atmospheric water tank
  • Brine kit: thermal insulation of hydraulic pipes fittings and pumps for low temperature units
  • Wind baffles kit
  • Threaded water connections kit (GAS)
  • Automatic water filling kit
  • Rubber anti-vibration mountings kit
  • Remote Panel
  • Sequencer for modular units
  • Wheels kit