ACT
PREMIUM REFRIGERATION DRYERS
Flow rate: 21 ÷ 18 000 m3/h
The ACT PREMIUM range of refrigeration dryers provides high performance and operational continuity even under extreme conditions.
Share
The ACT PREMIUM range of refrigeration dryers provides high performance and operational continuity even under extreme conditions. The ACT range has low pressure drops due to the ALU-DRY exchanger and is efficient due to the latest generation of compressors. It has a +3°C dew point, which is maintained even when operating conditions change using the three-way stainless steel hot gas by-pass valve. The range is designed to meet the most demanding applications up to a 300 m3/min. flow rate. The range standard electronic controllers are equipped with an RS485 port for connectivity to the company’s management system (INDUSTRY 4.0 ready). Water-cooled version on demand from ACT55. Non-wasteful capacitive drains are standard from ACT180 and optional for lower models.
MAXIMUM WORKING CONDITIONS
- Ambient temperature: + 50°C
- Inlet air pressure: 16 barg (ACT3÷18) - 14 barg
- Inlet air temperature: + 70°C
Data refer to the following nominal condition: ambient temperature + 25 °C; inlet air pressure 7 barg; inlet air temperature +35 °C.
- ALU DRY aluminium heat exchanger
- High-efficiency compressor
- Generously sized condenser unit
- Water pressure switch valve (water-cooled) (from ACT55)
- Digital controller DMC34 (ACT 3÷160) – DMC24 (ACT 180÷3000) RS485 modbus
- Refrigerant compressor thermal or thermo-ammeter protection
- Automatic condensation pressure control
- High compressor temperature protection (from ACT55)
- Refrigerant compressor phase sequence relay protection (3ph models)
- Refrigerant high- and low-pressure safety pressure switches (ACT 80÷3000 / ACT 55÷3000 3ph)
- Hot gas bypass valve
- Timed condensation drain (ACT 3÷160)
- Electronic level condensation drain (ACT 180÷3000)
- Compressor crankcase heater (3ph models only)
- On request models with different Power Supply and different connections [Ph/V/Hz]
- For ACT 180÷3000: counter-flanges and EN 1092-1 gaskets included.
TAC
Anti corrosion treatment
BK
Zero loss drain
WC
Water Cooling with plates condenser
WC TBH
Water cooling. Tube bundle condenser
SERVICE UNIT
8.000 hours maintenance kit for BK type electronic drain
BY-PASS
By-pass group
Main features
The ACT PREMIUM range of refrigeration dryers provides high performance and operational continuity even under extreme conditions. The ACT range has low pressure drops due to the ALU-DRY exchanger and is efficient due to the latest generation of compressors. It has a +3°C dew point, which is maintained even when operating conditions change using the three-way stainless steel hot gas by-pass valve. The range is designed to meet the most demanding applications up to a 300 m3/min. flow rate. The range standard electronic controllers are equipped with an RS485 port for connectivity to the company’s management system (INDUSTRY 4.0 ready). Water-cooled version on demand from ACT55. Non-wasteful capacitive drains are standard from ACT180 and optional for lower models.
MAXIMUM WORKING CONDITIONS
- Ambient temperature: + 50°C
- Inlet air pressure: 16 barg (ACT3÷18) - 14 barg
- Inlet air temperature: + 70°C
Technical Data
Data refer to the following nominal condition: ambient temperature + 25 °C; inlet air pressure 7 barg; inlet air temperature +35 °C.
Main Components
- ALU DRY aluminium heat exchanger
- High-efficiency compressor
- Generously sized condenser unit
- Water pressure switch valve (water-cooled) (from ACT55)
- Digital controller DMC34 (ACT 3÷160) – DMC24 (ACT 180÷3000) RS485 modbus
- Refrigerant compressor thermal or thermo-ammeter protection
- Automatic condensation pressure control
- High compressor temperature protection (from ACT55)
- Refrigerant compressor phase sequence relay protection (3ph models)
- Refrigerant high- and low-pressure safety pressure switches (ACT 80÷3000 / ACT 55÷3000 3ph)
- Hot gas bypass valve
- Timed condensation drain (ACT 3÷160)
- Electronic level condensation drain (ACT 180÷3000)
- Compressor crankcase heater (3ph models only)
- On request models with different Power Supply and different connections [Ph/V/Hz]
- For ACT 180÷3000: counter-flanges and EN 1092-1 gaskets included.
Brochure
Options and Accessories
TAC
Anti corrosion treatment
BK
Zero loss drain
WC
Water Cooling with plates condenser
WC TBH
Water cooling. Tube bundle condenser
SERVICE UNIT
8.000 hours maintenance kit for BK type electronic drain
BY-PASS
By-pass group